Ventilation MetaDesc http://www.sbengener.ru/zavod-volgavent/feed/atom.html 2024-04-27T20:24:00Z Joomla! 1.5 - Open Source Content Management Прайс-лист на вентиляцию 2008-11-26T21:56:03Z 2008-11-26T21:56:03Z http://www.sbengener.ru/en/nashi-tsceny/prayis-list-na-produktsciu-zavoda-volgavent.html Administrator neowisard@mail.ru {jfalternative}22|content| Sorry, no translation. Use http://translate.google.com{/jfalternative}<br/><p><a href="http://www.sbengener.ru/images/price/price.xls" target="_blank">Наши цены на системы вентиляции - " (Формат Excel - xls, 2 мегабайта)</a></p> {jfalternative}22|content| Sorry, no translation. Use http://translate.google.com{/jfalternative}<br/><p><a href="http://www.sbengener.ru/images/price/price.xls" target="_blank">Наши цены на системы вентиляции - " (Формат Excel - xls, 2 мегабайта)</a></p> Regulations on airways production 2008-09-11T21:37:42Z 2008-09-11T21:37:42Z http://www.sbengener.ru/en/izgotovlenie-vozduxovodov/normativnye-dokumenty-pri-proizvodstve-vozduxovodov.html Administrator neowisard@mail.ru <p>ВСН 353-86 "Design and exploitation of airways made of common parts". MinMountingSpecStroy USSR.<br /> Construction Regulations 41-01-2003 "Heating, ventilation and conditioning";<br />"Temporary standard for metal airways with circular section for aspiration systems";<br />Standard 4863-027-15185548-04 "Ventilating metal airways", "Lissant" cjs.;<br />Standard 2956-034-07502259-97 "Circular section airways with spiral-folded pipes", approved by Senior management of Marine register;<img src="http://www.sbengener.ru/images/stories/vent13-px.jpg" border="1" hspace="10" vspace="10" align="right" /><br />Standard 4863-030-15185548-04 "Ventilating metal diffusers and valves", "Lissant" cjs.;<br /> Construction Regulations 21-01-97 "Fire safety of buildings";<br />Fire safety regulations 105-95 "Category of buildings according to fire explosion and fire safety ";<br /> Fire safety regulations 241-97 "Ventilating fireproof valves";<br />Manual 6-91 to Construction Regulations 2.04.05-91 "Fireproof airways", "PromStroyProject". Equipment and technology of "Lissant" cjs. allows to produce ventilation elements which conform to:<br />EVROVENT 2/3 – European standard.<br />BS DW 142 – Great Britain standard.<br />SFS 3282, 3541 – Finland standard.<br />DIN 24 145 – German standard.</p> <p>Depending on conditions of ventilation system exploitation airways can be made of various materials. To transmit air of 80C and 60% humidity airways are made of:</p> <p>thin sheet cold-rolled zinked steel with 0,5-1,0 mm thickness, State standard 14918-80 ( 200-420 g of zinc for 1 m2 of steel)<br />thin sheet hot-rolled steel with 0,5-1,0 mm thickness, State standard 16523-70, State standard 19903-74 (steel without cover)###</p> <p>ВСН 353-86 "Design and exploitation of airways made of common parts". MinMountingSpecStroy USSR.<br /> Construction Regulations 41-01-2003 "Heating, ventilation and conditioning";<br />"Temporary standard for metal airways with circular section for aspiration systems";<br />Standard 4863-027-15185548-04 "Ventilating metal airways", "Lissant" cjs.;<br />Standard 2956-034-07502259-97 "Circular section airways with spiral-folded pipes", approved by Senior management of Marine register;<img src="http://www.sbengener.ru/images/stories/vent13-px.jpg" border="1" hspace="10" vspace="10" align="right" /><br />Standard 4863-030-15185548-04 "Ventilating metal diffusers and valves", "Lissant" cjs.;<br /> Construction Regulations 21-01-97 "Fire safety of buildings";<br />Fire safety regulations 105-95 "Category of buildings according to fire explosion and fire safety ";<br /> Fire safety regulations 241-97 "Ventilating fireproof valves";<br />Manual 6-91 to Construction Regulations 2.04.05-91 "Fireproof airways", "PromStroyProject". Equipment and technology of "Lissant" cjs. allows to produce ventilation elements which conform to:<br />EVROVENT 2/3 – European standard.<br />BS DW 142 – Great Britain standard.<br />SFS 3282, 3541 – Finland standard.<br />DIN 24 145 – German standard.</p> <p>Depending on conditions of ventilation system exploitation airways can be made of various materials. To transmit air of 80C and 60% humidity airways are made of:</p> <p>thin sheet cold-rolled zinked steel with 0,5-1,0 mm thickness, State standard 14918-80 ( 200-420 g of zinc for 1 m2 of steel)<br />thin sheet hot-rolled steel with 0,5-1,0 mm thickness, State standard 16523-70, State standard 19903-74 (steel without cover)###</p> Air-conditioning systems and ventilation 2008-09-09T20:36:27Z 2008-09-09T20:36:27Z http://www.sbengener.ru/en/proizvodstvo-sistem-ventilyatscii/sistemy-konditscionirovaniya-i-ventilyatscii.html Administrator neowisard@mail.ru <div style="margin-left: 10px; margin-top: 16px"> <h2><span class="style1"><br /> </span></h2> </div> <p> </p> <p align="justify">Correctly designed, professionally installed air-conditioning systems play major role in premises. Air making, favorable for people`s health is not only humanity feelings, but also accordance with requirements of technological process, equipment and construction preservation, materials, products, etc. Companies very often need ideal controllable climate. <br /> <br /> Ventilation system types.<br /> <br /> Ventilation can be blowing and exhaust. Principle of operation of blowing: inflow of fresh air into the, exhaust – selection of polluted air out of the room. Combined system is often used: blowing-exhaust, which allows achieving bigger effect when airing the room.</p> <p> </p> <p align="justify">What`s the difference between air conditioning and ventilation?<br /> <br /> Very often it`s important not only to arrange air exchange in the room, but also fix special parameters for the air. Irrespective of season, of heat and moisture parameters, air conditioning systems sustain necessary parameters of air exchange.</p> <p> </p> <p align="justify">Air conditioning types.<br /> <br /> In general, air conditioners are divided into 2 big groups: home and industrial. In its turn, industrial include – ported conditioner of high power, sensitive, central and systems of chiller-funk oil. These are systems with power more than 20 — 25 KW. They are used for servicing residential and administrative buildings, sales areas and sport centers, industrial and specialized rooms - area more than 300 square meters.</p> <p> </p> <p align="justify">Ventilation and air conditioning assembling.<br /> <br /> Company «VolgaVent» offers professional assembling of ventilation and air conditioners. Our activity includes all steps starting from components delivery and designing and finishing with systems installation. <br /> Experienced employees will do job on time. Our company offers ready, already checked solutions, what helps to avoid any problems in job.</p> <p> </p> <p align="justify">Conditioning system design. <br /> Specialists of our department design ventilation and any conditioning systems. Unique work experience and rich technical resources allow solving any technical task for our customers. In case if project has its peculiarities, our designers may offer you several types of engineering solutions. They work out ways of decreasing total cost of project without losing functional capability of the system.</p> <p> </p> <p align="justify">Ventilation layout.<br /> <br /> This process is quite complicated and important, what means compulsory appeal to professionals. <br /> <br /> Layout starts from defining necessary air amount, necessary for airing the room. After that – principal scheme of ventilation is made in accordance with all aerodynamic properties. At the end equipment is chosen and installed, controlling system is set up. Layout made by specialists of «VolgaVent» company, meet modern requirements and regulations.</p> <div style="margin-left: 10px; margin-top: 16px"> <h2><span class="style1"><br /> </span></h2> </div> <p> </p> <p align="justify">Correctly designed, professionally installed air-conditioning systems play major role in premises. Air making, favorable for people`s health is not only humanity feelings, but also accordance with requirements of technological process, equipment and construction preservation, materials, products, etc. Companies very often need ideal controllable climate. <br /> <br /> Ventilation system types.<br /> <br /> Ventilation can be blowing and exhaust. Principle of operation of blowing: inflow of fresh air into the, exhaust – selection of polluted air out of the room. Combined system is often used: blowing-exhaust, which allows achieving bigger effect when airing the room.</p> <p> </p> <p align="justify">What`s the difference between air conditioning and ventilation?<br /> <br /> Very often it`s important not only to arrange air exchange in the room, but also fix special parameters for the air. Irrespective of season, of heat and moisture parameters, air conditioning systems sustain necessary parameters of air exchange.</p> <p> </p> <p align="justify">Air conditioning types.<br /> <br /> In general, air conditioners are divided into 2 big groups: home and industrial. In its turn, industrial include – ported conditioner of high power, sensitive, central and systems of chiller-funk oil. These are systems with power more than 20 — 25 KW. They are used for servicing residential and administrative buildings, sales areas and sport centers, industrial and specialized rooms - area more than 300 square meters.</p> <p> </p> <p align="justify">Ventilation and air conditioning assembling.<br /> <br /> Company «VolgaVent» offers professional assembling of ventilation and air conditioners. Our activity includes all steps starting from components delivery and designing and finishing with systems installation. <br /> Experienced employees will do job on time. Our company offers ready, already checked solutions, what helps to avoid any problems in job.</p> <p> </p> <p align="justify">Conditioning system design. <br /> Specialists of our department design ventilation and any conditioning systems. Unique work experience and rich technical resources allow solving any technical task for our customers. In case if project has its peculiarities, our designers may offer you several types of engineering solutions. They work out ways of decreasing total cost of project without losing functional capability of the system.</p> <p> </p> <p align="justify">Ventilation layout.<br /> <br /> This process is quite complicated and important, what means compulsory appeal to professionals. <br /> <br /> Layout starts from defining necessary air amount, necessary for airing the room. After that – principal scheme of ventilation is made in accordance with all aerodynamic properties. At the end equipment is chosen and installed, controlling system is set up. Layout made by specialists of «VolgaVent» company, meet modern requirements and regulations.</p> Production of airways 2008-06-13T19:30:28Z 2008-06-13T19:30:28Z http://www.sbengener.ru/en/izgotovlenie-vozduxovodov/proizvodstvo-vozduxovodov.html Administrator neowisard@mail.ru <p><img src="http://www.sbengener.ru/images/stories/vent13-px.jpg" border="0" alt="Airways" />Airways are made out of galvanized steel in accordance with State Standard(24751-81) <strong><br />Tightness of all details - class &lt;П&gt;( compact)</strong><br /> Juncture of airways – by nipples using silicon sealing material and fixing by фиксацией rivet and bolts. Rubber juncture can be used for tighter airways.</p> <p><img src="http://www.sbengener.ru/images/stories/vent13-px.jpg" border="0" alt="Airways" />Airways are made out of galvanized steel in accordance with State Standard(24751-81) <strong><br />Tightness of all details - class &lt;П&gt;( compact)</strong><br /> Juncture of airways – by nipples using silicon sealing material and fixing by фиксацией rivet and bolts. Rubber juncture can be used for tighter airways.</p>